Our conductive copper foil tape combines a dead-soft copper foil backing with an electrically conductive acrylic adhesive. It provides reliable electrical continuity through the adhesive layer and is designed for EMI/RFI shielding, grounding, static discharge, cable shielding, PCB repair, and electronic enclosure applications.

Available in custom widths, roll lengths, sheets, and precision die-cut parts for electronics, electrical equipment, automotive components, and industrial assembly.

  • Copper Foil Thickness: 25 μm ± 3 μm
  • Conductive Adhesive Thickness: 35 μm ± 5 μm
  • Available Widths: 2–390 mm
  • Standard Roll Length: Up to 50 m
  • Temperature Resistance: 90–120°C
  • Custom Processing: Slitting, laminating, kiss cutting, and die cutting

Custom sizes, samples, technical data sheets, and OEM packaging are available.

Get a Quote Whatsapp

Conductive Copper Foil Tape Specifications

Our conductive copper foil tape combines flexible copper foil with electrically conductive acrylic adhesive, providing reliable conductivity through the adhesive layer. It is suitable for EMI/RFI shielding, grounding, static discharge, PCB assembly, cable wrapping, and electronic enclosure applications.

Property Specification
Product Type Single-sided conductive copper foil tape
Copper Foil Dead-soft electrolytic copper foil
Copper Foil Thickness 25 μm ± 3 μm
Adhesive Type Electrically conductive acrylic adhesive
Adhesive Thickness 35 μm ± 5 μm
Total Tape Thickness Approx. 60 μm, excluding release liner
Adhesive Conductivity Conductive through the adhesive layer
Standard Width 2–390 mm
Roll Length 20 m, 25 m, 50 m or customized
Release Liner Paper or PET release liner
Operating Temperature -20°C to 90°C
Short-Term Temperature Up to 120°C
Surface Finish Natural copper
Solderability Copper surface can be soldered
Custom Processing Slitting, laminating, sheets, kiss cutting and die cutting
Typical Applications EMI/RFI shielding, grounding, PCB repair, cable shielding and electronic assembly
Compliance RoHS and REACH available upon request
Packaging Standard export packaging or customized OEM packaging

Custom foil thicknesses, adhesive systems, widths, roll lengths and die-cut shapes are available according to your application. Electrical resistance, peel adhesion and temperature test data can be provided with the technical data sheet.

bg img 2

Foil Copper Tape Applications

Inquiry Now
copper foil tape

Copper Foil Adhesive Tape Features

  1. Copper Foil Thickness: 25µ ±3 Conductive
  2. Adhesive Thickness: 35µ ±5
  3. High temperature resistance (90-120°C)Double-sided conductive. acid/alkali/solvent resistance, strong holding power,clean removal
  • EMI/RFI attenuation – Creates a continuous copper path across seams and covers, reducing radiated and conducted noise.
  • Grounding continuity – With double-sided conductive adhesive, current flows through overlaps and the bondline—ideal for seams and patching.
  • Formable backing – Dead-soft copper conforms to radii, screw bosses, and surface texture; can be soldered where allowed.
  • Low-resistance paths – Overlaps can be designed for milliohm-level continuity when surfaces are prepped and pressure is correct.
  • Flexible configurations – Choose conductive or non-conductive adhesive; liner for easy handling; anti-oxidation treatments available by grade.
  • Custom formats – Slit-to-width, kiss-cut sheets, and die-cuts (tabs, washers, rings) for repeatable assembly.
Inquiry Now
bg img 2

Why Choose Copper Foil Tape

Inquiry Now
copper foil shielding enclosure 3

Quality and Handling

  • Storage: Cool, dry; keep rolls bagged; avoid prolonged exposure before install.
  • Handling: Use gloves; avoid touching the adhesive; keep liner on until placement.
  • Traceability: Retain core/pack labels; rotate stock (FIFO).
  • Soldering: Remove adhesive/liner at solder point; control heat; validate adhesion after solder cools.

Copper Tape Foil Performance

Property Typical Values / Options
Backing Dead-soft copper foil (e.g., 18–50 µm common; others on request)
Adhesive systems Conductive acrylic (through-adhesive conduction) or non-conductive acrylic (mechanical hold)
Bondline behavior Electrical continuity across overlaps with conductive adhesive; use hardware/primer if non-conductive
Resistance (across overlap) Low milliohm potential with clean surfaces, firm pressure, and adequate overlap (design-dependent)
Heat tolerance Typically 90–120 °C continuous for adhesive; copper backing tolerates higher; verify by grade
Shielding effectiveness Application-dependent; improved by coverage, overlap strategy, and compression
Standard lengths 20–50 m rolls typical; customs available
Widths Stock metric/imperial; slit-to-width with tight tolerances
Formats Rolls, kiss-cut sheets, precision die-cuts (disks, frames, washers, tabs)
Surface Bare copper; optional anti-oxidation/treated surfaces (grade-dependent)
Solderability Copper is solderable; confirm adhesive/liner removal and heat limits before soldering

Important: Adhesive temperature and time at temperature govern long-term performance. For sustained high heat or aggressive environments, validate with your exact profile.

Copper Foil Conductive Tape Selection Guide

Need / Scenario Adhesive Type Foil Thickness Format Why this works
Seam shielding with overlap Conductive acrylic 25 µm 12–25 mm rolls Conducts through the bondline; overlap forms a continuous path.
Ground patch to chassis Conductive acrylic 25–35 µm Die-cut tabs + roll Low-resistance tie-ins at screws or star washers.
Cable shield wrap / harness Non-conductive (then hardware bond) or conductive 18–25 µm 12–18 mm rolls Choose conductive for full wrap continuity; non-conductive if bonding mechanically.
Prototype fixes on PCBs Conductive acrylic 18–25 µm Kiss-cut sheets Thin foil conforms; easy peel-stick-test-revise workflow.
Instrument cavity/guitar Conductive acrylic 25–35 µm 25–50 mm rolls Reliable continuity across overlaps; conforms to curves.
Rough surfaces / texture Conductive acrylic 35–50 µm 18–24 mm rolls Thicker foil bridges texture; adhesive conducts through bondline.

Conductive vs. Non-Conductive Copper Foil Tape

Both types use copper foil as the backing, but the main difference is whether electricity can pass through the adhesive layer.

Feature Conductive Copper Foil Tape Non-Conductive Copper Foil Tape
Adhesive Type Conductive acrylic adhesive Standard acrylic adhesive
Through-Adhesive Conductivity Yes No
Electrical Continuity Easier across bonded surfaces and overlaps Requires direct copper-to-copper contact
EMI/RFI Shielding Ideal for seams, enclosures and grounding paths Suitable mainly for surface shielding
Typical Applications Electronics, PCB grounding, cable shielding and enclosures Crafts, decorative uses and general surface shielding
Cost Slightly higher More economical

Key specs (CU25)

Copper Foil Thickness 25 µ ± 3
Adhesive thickness 35 µ ± 5
Resistance value ≈ 0.05 Ω
Heat resistance 90–120 °C
Available widths 2–390 mm • 50 m roll • 3″ core

How To Install For Low Resistance (step-by-step)

  1. Prep the surface – Clean, dry, and lightly abrade paint/anodize if allowed. The goal is intimate contact and consistent pressure.
  2. Plan the path – Sketch the route from the noise source to ground; minimize sharp bends; choose overlap points.
  3. Lay with steady tension – Apply the tape smoothly; avoid wrinkles that can trap air and raise impedance.
  4. Create overlaps – Use 6–12 mm overlap on seams; burnish firmly with a roller to maximize contact.
  5. Tie into ground – Expose copper at the bond point; use hardware (e.g., screw + star washer) or solder where permitted.
  6. Verify continuity – Measure point-to-point resistance with a multimeter (mΩ target). Log values for QA.
  7. Stabilize – For high-vibration zones, add mechanical support (fasteners or strain relief) as needed.
copper foil shielding enclosure 2

Troubleshooting:

  1. High resistance at overlaps → Increase pressure, enlarge the overlap, or clean surfaces; confirm adhesive is conductive.
  2. Adhesive lift on texture → Step up to thicker foil, pre-roll with pressure, or consider a primer where compatible.
  3. Oxidation over time → Use treated surfaces/anti-oxidation grades, or seal edges with compatible coatings.

Compatibility and Limitations:

  1. Adhesive heat limits govern long-term performance; the copper backing itself handles higher temperatures.
  2. For outdoor/corrosive environments, consider protective topcoats or sealed assemblies.
  3. When mechanical robustness is mission-critical, use hardware bonds in addition to tape (belt-and-suspenders approach).
  4. If you only need high-temp masking (not conduction), select Green PET or Polyimide instead.

Engineering Case: EMI Shielding for Electronic Enclosures

An electronic equipment manufacturer needed to improve electrical continuity across metal enclosure seams and simplify the shielding installation process.

We recommended 25 μm conductive copper foil tape with conductive acrylic adhesive. Custom slit widths were produced to match the enclosure joints, while die-cut copper foil patches were supplied for grounding points and irregular areas.

Before production, samples were checked for adhesion, dimensional accuracy, through-adhesive conductivity, and continuity across overlapping seams.

The customized tape reduced manual cutting during assembly and provided reliable electrical contact across enclosure joints and grounding areas.

Solution supplied:

  • 25 μm conductive copper foil tape
  • Custom widths and roll lengths
  • Die-cut grounding patches
  • Adhesion and conductivity testing
key performance checks for conductive copper foil tape

FAQS

Conductive copper foil tape is used for EMI/RFI shielding, electrical grounding, static discharge control, PCB repair, cable wrapping, electronic enclosures, and other applications requiring electrical continuity.

Clean and dry the surface, apply the tape smoothly, and press it firmly with a roller. For shielding seams, overlap adjacent strips and verify electrical continuity after installation.

Yes. The exposed copper surface can be soldered. Keep the soldering time short and control the heat to avoid damaging the adhesive layer.

Conductive adhesive allows electricity to pass through the adhesive layer, making it suitable for grounding and EMI shielding. Non-conductive adhesive provides mechanical bonding but requires direct copper contact for electrical continuity.

A 6–12 mm overlap is generally suitable for shielding seams. Firm pressure and clean surfaces help improve contact and reduce resistance.

Resistance may increase because of loose overlaps, oxidation, contamination, moisture, or insufficient pressure. Clean the contact area, reapply pressure, and consider anti-oxidation treatment for demanding environments.

en_USEN